석션파일 방파제기초

Title
석션파일 방파제기초
Alternative Title
Suction Piles for Breakwater Foundation
Author(s)
Bang; Cho; Kwag; 권오순
KIOST Author(s)
Kwon, O Soon(권오순)
Alternative Author(s)
권오순
Publication Year
2007-10-01
Abstract
A new breakwater system, utilizing gravity-type concrete caisson superstructure on top of concrete suction piles that act as the subsurface foundations was designed and successfully installed in the field as part of an experimental project between 2004 and 2007. The design utilized three concrete caissons supported by eight suction piles. Suction piles have a diameter of 11 meters and the rectangular concrete caisson have dimensions of 21.4 meters by 16 meters by 18 meters. Instrumentation during suction pile installation includes the measurements of the suction pressure, pile penetration, and pile tilts.
URI
https://sciwatch.kiost.ac.kr/handle/2020.kiost/41176
Bibliographic Citation
US-Korea Conference on Science, Technology and Entrepreneurship 2007, pp.1 - 7, 2007
Type
Conference
Language
English
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.