Biocompatibility and sub-chronic toxicity studies of phlorotannin/polycaprolactone coated trachea tube for advancing medical device applications SCIE SCOPUS

Cited 0 time in WEB OF SCIENCE Cited 0 time in Scopus
Title
Biocompatibility and sub-chronic toxicity studies of phlorotannin/polycaprolactone coated trachea tube for advancing medical device applications
Author(s)
Kim, Tae-Hee; Heo, Seong Yeong; Oh, Gun-Woo; Park, Won Sun; Jung, Won-Kyo
KIOST Author(s)
Heo, Seong Yeong(허성영)
Alternative Author(s)
허성영
Publication Year
2024-02
Abstract
The phlorotannin-polycaprolactone-coated endotracheal tube (PP tube) has been developed with the aim of preventing tracheal stenosis that can result from endotracheal intubation, a factor that can lead to a serious airway obstruction. Its preventive efficacy has been assessed through both in vitro and in vivo investigations. However, there is a lack of studies concerning its biocompatibility and sub-chronic toxicity in animal models, a crucial factor to ensure the safety of its usage as a functional endotracheal tube. Thus, this study aimed to evaluate the biocompatibility and sub-chronic (13 weeks) toxicity of the PP tube through L929 cell line and diverse in vivo models. The cytotoxicity testing was performed using the extracts of PP tube on L929 cells for 72 h. Furthermore, other tests conducted on animal models, including ICR mice (acute systemic toxicity), New Zealand white rabbit (intradermal reactivity and pyrogen tests), guinea pig (maximization sensitization), and Sprague Dawley rats (sub-chronic toxicity). In both biocompatibility and sub-chronic toxicity analyses, no significant adverse effects are observed in the groups exposed to the PP tube, when compared to control group. Altogether, the findings suggested that the PP tube exhibits relative non-toxic and safety, supporting its suitability for clinical usage. However, extended periods of intubation may produce mild irritant responses, highlighting the clinical caution of limiting intubation duration to less than 13 weeks. © The Author(s) 2024.
ISSN
2045-2322
URI
https://sciwatch.kiost.ac.kr/handle/2020.kiost/45419
DOI
10.1038/s41598-024-54684-8
Bibliographic Citation
Scientific Reports, v.14, 2024
Publisher
Nature Publishing Group
Keywords
Biocompatibility; Endotracheal tube; Medical device; Phlorotannin; Sub-chronic toxicity
Type
Article
Language
English
Document Type
Article
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse