TRACE URANIUM ASSAY USING INFRARED PHOTO DIODE ELECTRODES SCIE SCOPUS

Cited 1 time in WEB OF SCIENCE Cited 1 time in Scopus
Title
TRACE URANIUM ASSAY USING INFRARED PHOTO DIODE ELECTRODES
Author(s)
Ly, Suw Young; Choa, Sung Hoon; Shin, Myoung Ho; Kim, Seong-Ryul; Yoo, Hai-Soo; Shin, Hong Joong; Jung, Young Sam; Choi, Jin Bum
Alternative Author(s)
김성렬; 유해수
Publication Year
2010
Abstract
A voltammetric assay of uranium using an infrared photo diode electrode (DE) was conducted. A square wave stripping cathodic peak appeared at -0.2V (vs. Ag/AgCl/KCl) attributed to the reduction of uranium ion. Under optimum analytical conditions, various conventional working electrodes were compared. The analytical working range was found to be 0.1-1.1 mg/L DE, precision range of R-2 = 0.9581, and the high range was obtained at 5-130 mg/L with precision R-2 = 0.9981. Here, an ammonium phosphate electrolyte pH strength of 2.3, an accumulation time of 0 sec, and an accumulation potential of 0.5V were used. Under these conditions, the relative standard deviation of 0.5 mg/L was 1.69%. The detection limit was found to be 0.35 ugL(-1) (1.49 x 10(9) M) (S/N = 3). The methods developed in this study are applicable in micro-array multi-sensor systems or other analytical instrumental systems.
ISSN
0003-2719
URI
https://sciwatch.kiost.ac.kr/handle/2020.kiost/4204
DOI
10.1080/00032710903502157
Bibliographic Citation
ANALYTICAL LETTERS, v.43, no.9, pp.1471 - 1480, 2010
Publisher
TAYLOR & FRANCIS INC
Subject
SAMPLES; SPECTROMETRY; DEPOSIT; RATIOS
Keywords
Assay; Infrared photo diode; Uranium; Voltammetry
Type
Article
Language
English
Document Type
Article
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse