울돌목 시험조류발전소에 적용된 SHM 시스템의 소개

Title
울돌목 시험조류발전소에 적용된 SHM 시스템의 소개
Alternative Title
Introduction to Structural Health Monitoring System on Uldolmok Tidal Current Power Plant
Author(s)
이진학; 박우선; 박진순; 이광수
KIOST Author(s)
Yi, Jin-Hak(이진학)Park, Woo Sun(박우선)Park, Jin Soon(박진순)
Alternative Author(s)
이진학; 박우선; 박진순; 이광수
Publication Year
2009-10-14
Abstract
In this paper, the structural health monitoring system for “Uldolmok Tidal Current Power Plant (TCPP)” is briefly introduced and the measured data obtained up to now are analyzed. TCPP is basically constructed in the ocean area with high current speed, and therefore the current loading is governing the structural safety than the wave or wind loadings. Usually the soft soils are eroded due to the current and the soft and hard rocks are composing the seabed in strait which tidal current of high speed. Therefore the coring is not so easy due to rock seabed condition and also the operational time is very limited. And also the structural members should not be over designed with large size of steel pipe not to obstruct the tidal current. Due to the difficulties in coastal construction, relatively severe current loadings, and optimized slender structural members, it is very important to monitor the structural safety of the tidal current power plant in normal operation condition and also in severe storm condition. However, the sensor installation is much more difficult for TCPP structure than the in-land structures such as bridges and buildings since the sensors should be fully water-proof and the cables should be able to endure the corrosive condition. In this study, we installed the sensors under the sea level and are going to install the sensors outside sea in this year after the structure is constructed. Now the structure is under construction. The conventional type strain sensors (KM-100B) and smart FBG optical sensors (from Micron Optics) were installed in the bottom part of the jacket legs to measure the dynamic and static strains and the MFC (Macro Fiber Composite) sensors were also installed at the same location to measure the impedance change due to loading and corrosion conditions. Guidelines.
URI
https://sciwatch.kiost.ac.kr/handle/2020.kiost/29331
Bibliographic Citation
The 5th International Conference on Asian and Pacific Coasts (APAC 2009), pp.321 - 327, 2009
Publisher
World Scientific Publishing Company
Type
Conference
Language
English
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse