A Study on Confined Effect of Double Skinned Composite Tubular Column under Axial Force
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 원덕희 | - |
dc.contributor.author | 윤나리 | - |
dc.contributor.author | 한택희 | - |
dc.contributor.author | 이기세 | - |
dc.contributor.author | 강영종 | - |
dc.date.accessioned | 2020-07-16T06:30:59Z | - |
dc.date.available | 2020-07-16T06:30:59Z | - |
dc.date.created | 2020-02-11 | - |
dc.date.issued | 2014-01-01 | - |
dc.identifier.uri | https://sciwatch.kiost.ac.kr/handle/2020.kiost/26451 | - |
dc.description.abstract | Columns are the main members resisting axial force and lateral seismic force. Therefore, the behavior of a column has a significant effect on the whole structure. Recently, steel composite column is built in the field of architecture. Many of constructed composite column were concrete filled tube 9CFT). CFT has excellent performance againstseismic force. however, when applied to the pier of a bridfe, there is uneconomical or massive porblem because they should be fully filled with concrete. To overcome these disadvantages, hollw CFT columns were suggested. They are impossible to reduce design seismic force and self-weight of the column....Sructural trend analysis through comparing hollow CFT column. ANd present proportion of external confined stress and internal confined stress through selection of an important parameter by parametric study suggested an modified formular about yield failure condition and buckling failure condition used results.any of constructed composite column were concrete filled tube 9CFT). CFT has excellent performance againstseismic force. however, when applied to the pier of a bridfe, there is uneconomical or massive porblem because they should be fully filled with concrete. To overcome these disadvantages, hollw CFT columns were suggested. They are impossible to reduce design seismic force and self-weight of the column....Sructural trend analysis through comparing hollow CFT column. ANd present proportion of external confined stress and internal confined stress through selection of an important parameter by parametric study suggested an modified formular about yield failure condition and buckling failure condition used results. | - |
dc.description.uri | 1 | - |
dc.language | English | - |
dc.publisher | 한국강구조학회-일본토목학회 | - |
dc.relation.isPartOf | 11h Korea-Japan Joint Symposium on Steel Bridges | - |
dc.title | A Study on Confined Effect of Double Skinned Composite Tubular Column under Axial Force | - |
dc.type | Conference | - |
dc.citation.conferencePlace | KO | - |
dc.citation.endPage | 394 | - |
dc.citation.startPage | 386 | - |
dc.citation.title | 11h Korea-Japan Joint Symposium on Steel Bridges | - |
dc.contributor.alternativeName | 원덕희 | - |
dc.contributor.alternativeName | 한택희 | - |
dc.identifier.bibliographicCitation | 11h Korea-Japan Joint Symposium on Steel Bridges, pp.386 - 394 | - |
dc.description.journalClass | 1 | - |