Pico molar assay of riboflavin in human urine using voltammetry SCIE SCOPUS

DC Field Value Language
dc.contributor.author Ly, Suw Young -
dc.contributor.author Yoo, Hai Soo -
dc.contributor.author Ahn, Joon Young -
dc.contributor.author Nam, Kwang Hee -
dc.date.accessioned 2020-04-20T07:43:41Z -
dc.date.available 2020-04-20T07:43:41Z -
dc.date.created 2020-02-04 -
dc.date.issued 2011-07-01 -
dc.identifier.issn 0308-8146 -
dc.identifier.uri https://sciwatch.kiost.ac.kr/handle/2020.kiost/3843 -
dc.description.abstract Using a new type of DNA and carbon nano tube (CNT) mixed paste electrode using cyclic and square wave anodic stripping voltammetric (SWASV) methods, this study presents an assay of riboflavin (RF) under optimum conditions. Results of the experiment yielded a low working concentration range of nanograms with 1-10 and 10-170 ng L-1 and 5-105 mu g L-1, at an accumulation time of 80 s in a 0.1 M H3PO4 electrolyte solution. A relative standard deviation of 30 mu g L-1 was observed at an accuracy level of 0.1164% (n = 15) under optimum conditions. The detection limit (S/N) was pegged at 0.2 ng L-1 (5.31 x 10(-13) mol L-1 RF). The proposed method was successfully applied to an actual human urine and drug sample, and can be applied to assays of other biological samples. (C) 2011 Elsevier Ltd. All rights reserved. -
dc.description.uri 1 -
dc.language English -
dc.publisher ELSEVIER SCI LTD -
dc.subject ADSORPTIVE STRIPPING VOLTAMMETRY -
dc.subject ELECTRODE -
dc.subject MEDIA -
dc.title Pico molar assay of riboflavin in human urine using voltammetry -
dc.type Article -
dc.citation.endPage 274 -
dc.citation.startPage 270 -
dc.citation.title FOOD CHEMISTRY -
dc.citation.volume 127 -
dc.citation.number 1 -
dc.contributor.alternativeName 유해수 -
dc.identifier.bibliographicCitation FOOD CHEMISTRY, v.127, no.1, pp.270 - 274 -
dc.identifier.doi 10.1016/j.foodchem.2010.12.107 -
dc.identifier.wosid 000288304900040 -
dc.type.docType Article -
dc.description.journalClass 1 -
dc.subject.keywordPlus ADSORPTIVE STRIPPING VOLTAMMETRY -
dc.subject.keywordPlus ELECTRODE -
dc.subject.keywordPlus MEDIA -
dc.subject.keywordAuthor Riboflavin -
dc.subject.keywordAuthor Voltammetry -
dc.subject.keywordAuthor DNA -
dc.subject.keywordAuthor Graphite nanotube -
dc.subject.keywordAuthor Paste electrode -
dc.subject.keywordAuthor Urine -
dc.relation.journalWebOfScienceCategory Chemistry, Applied -
dc.relation.journalWebOfScienceCategory Food Science & Technology -
dc.relation.journalWebOfScienceCategory Nutrition & Dietetics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.relation.journalResearchArea Chemistry -
dc.relation.journalResearchArea Food Science & Technology -
dc.relation.journalResearchArea Nutrition & Dietetics -
Appears in Collections:
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse