지반오염 조사에 대한 비저항콘의 적용성에 대한 실험적 연구

Title
지반오염 조사에 대한 비저항콘의 적용성에 대한 실험적 연구
Alternative Title
Laboratory study on the applicability of resistivity cone for investigation of subsurface contamination
Author(s)
오명학; 김용성; 박준범; 권오순
KIOST Author(s)
Oh, Myounghak(오명학)Kwon, Osoon(권오순)
Publication Year
2008-04-01
Abstract
Laboratory experiments were performed on carefully prepared soil layers to investigate the sensitivity of the electrical resistivity of cone on water content and different types of contaminants including heavy metal and petroleum hydrocarbon. Theoretical resistivity equation considering the electric current flow in 3-dimensional full-space around the cone was derived to provide a means of computing the geometric factor for diameter of cone and electrode spacings. Laboratory model test results showed that electrical resistivity measured by cone showed high applicability to be used in detecting the heavy metal contamination in the saturated subsurface and the diesel fuel plume floating above the groundwater table, though it might be difficult to detect contamination in the unsaturated layer.
URI
https://sciwatch.kiost.ac.kr/handle/2020.kiost/30089
Bibliographic Citation
Proceedings of the third International Conference on Site Characterization, pp.737 - 743, 2008