충격진동시험을 이용한 케이슨식 방파제의 동적특성 평가와 수치해석모델의 검증

DC Field Value Language
dc.contributor.author 이진학 -
dc.contributor.author 박우선 -
dc.contributor.author 이소영 -
dc.contributor.author 김정태 -
dc.contributor.author 서춘교 -
dc.date.accessioned 2020-07-16T08:31:37Z -
dc.date.available 2020-07-16T08:31:37Z -
dc.date.created 2020-02-11 -
dc.date.issued 2013-07-03 -
dc.identifier.uri https://sciwatch.kiost.ac.kr/handle/2020.kiost/26875 -
dc.description.abstract In this study, ambient and forced vibration tests are proposed to evaluate dynamic characteristics of a caisson-type breakwater including natural frequencies and modal damping ratios, and the feasibility of numerical analysis model with fluid-structure-soil interaction effects, which plays an important role to evaluate structural performance and safety, is investigated by comparing the numerical results with experimental results. Oryukdo breakwater in Busan, Korea is utilized as a target structure, and this breakwater was once heightened by installing additional parapet structures as amount of about 4 m to improve the harbor tranquility in 2005. Two times of vibration tests were carried out in 2000 (before heightening) and in 2011 (after heightening). In the first test, most caissons were tested while one caisson was tested in 2011. It is found that natural frequencies are reduced as amount of 1.7 &#8211 4.3 % after heightening, and similar results are observed from the numerical analysis. It is also found that forced vibration tests can make more reasonable results than ambient vibration tests. Even though there is some degree of discrepancy between experimental and numerical results, numerical analysis can be carried out to analyze dynamic characteristics and evaluate the structural performance and safety.id-structure-soil interaction effects, which plays an important role to evaluate structural performance and safety, is investigated by comparing the numerical results with experimental results. Oryukdo breakwater in Busan, Korea is utilized as a target structure, and this breakwater was once heightened by installing additional parapet structures as amount of about 4 m to improve the harbor tranquility in 2005. Two times of vibration tests were carried out in 2000 (before heightening) and in 2011 (after heightening). In the first test, most caissons were tested while one caisson was tested in 2011. It is found that natural frequencies are reduced as amount of 1.7 &#8211 4.3 % after heightening, and similar results are observed from the numerical analysis. It is also found that forced vibration tests can make more reasonable results than ambient vibration tests. Even though there is some degree of discrepancy between experimental and numerical results, numerical analysis can be carried out to analyze dynamic characteristics and evaluate the structural performance and safety. -
dc.description.uri 1 -
dc.language English -
dc.publisher The International Society of Offshore and Polar Engineers -
dc.relation.isPartOf ISOPE-2013 Conference -
dc.title 충격진동시험을 이용한 케이슨식 방파제의 동적특성 평가와 수치해석모델의 검증 -
dc.title.alternative Evaluation of Vibration Characteristics of Caisson-Type Breakwater Using Impact Vibration Tests and Validation of Numerical Analysis Model -
dc.type Conference -
dc.citation.conferencePlace US -
dc.citation.endPage 1209 -
dc.citation.startPage 1202 -
dc.citation.title ISOPE-2013 Conference -
dc.contributor.alternativeName 이진학 -
dc.contributor.alternativeName 박우선 -
dc.identifier.bibliographicCitation ISOPE-2013 Conference, pp.1202 - 1209 -
dc.description.journalClass 1 -
Appears in Collections:
Marine Industry Research Division > Ocean Space Development & Energy Research Department > 2. Conference Papers
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse