수조실험을 이용한 멀티빔 음향측심기 측심 성능 평가 : 예비실험결과
-
Title
- 수조실험을 이용한 멀티빔 음향측심기 측심 성능 평가 : 예비실험결과
-
Alternative Title
- Performance Evaluation of Multi-Beam Echo Sounder in water tank : Preliminary Results
-
Author(s)
- 고지은; 박요섭; 장남도; 정섬규; 이용국
- KIOST Author(s)
- Koh, Ji Eun(고지은); Park, Yo Sup(박요섭); Jang, Nam Do(장남도); Jung, Seom Kyu(정섬규); Lee., Yong Kuk(이용국)
-
Alternative Author(s)
- 고지은; 박요섭; 장남도; 정섬규; 이용국
-
Publication Year
- 2013-11-14
-
Abstract
- The purpose of this validation test is to study the evaluation methods of sounding and spatial resolution, and to test the comparative validity of the methods. Test was performed in water tank of Korea Hydrographic and Oceanographic Administration placed at Busan. The size of water tank is 50m in length, 15m in width and 5~10m in depth.. The MBES we evaluated were Delta-T(260kHz, 3°) of Imagenex, 2024(200 ~ 400 kHz, 0.5°) of R2Sonic and Seabat 7125(400 kHz, 0.5°) of Reson. First, to evaluate accuracy of a sounding the depth, we acquired data after setting a separation distance is 40m. Then we performed same way with changing separation distances - 30, 20, 10m. Next, spatial resolution is assessed via detection performance. After installing artificial structures (cube shape, 50cm×50cm×50cm), we recorded soundings. While testing, values of GPS, motion sensor and Sound velocity are treated as constant to only consider a performance of MBES. And we acquired all data using software, HySweep of Hypack to prevent a occurrence of error.tration placed at Busan. The size of water tank is 50m in length, 15m in width and 5~10m in depth.. The MBES we evaluated were Delta-T(260kHz, 3°) of Imagenex, 2024(200 ~ 400 kHz, 0.5°) of R2Sonic and Seabat 7125(400 kHz, 0.5°) of Reson. First, to evaluate accuracy of a sounding the depth, we acquired data after setting a separation distance is 40m. Then we performed same way with changing separation distances - 30, 20, 10m. Next, spatial resolution is assessed via detection performance. After installing artificial structures (cube shape, 50cm×50cm×50cm), we recorded soundings. While testing, values of GPS, motion sensor and Sound velocity are treated as constant to only consider a performance of MBES. And we acquired all data using software, HySweep of Hypack to prevent a occurrence of error.
-
URI
- https://sciwatch.kiost.ac.kr/handle/2020.kiost/26541
-
Bibliographic Citation
- 한국수로학회 국제추계학술대회, pp.207 - 210, 2013
-
Publisher
- 한국수로학회
-
Type
- Conference
-
Language
- English
- Files in This Item:
-
There are no files associated with this item.
Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.