Structural stability of cable-stayed bridges SCIE SCOPUS KCI

DC Field Value Language
dc.contributor.author Kim, Seungjun -
dc.contributor.author Won, Deok Hee -
dc.contributor.author Lee, Keesei -
dc.contributor.author Kang, Young Jong -
dc.date.accessioned 2020-04-20T03:25:45Z -
dc.date.available 2020-04-20T03:25:45Z -
dc.date.created 2020-01-28 -
dc.date.issued 2015-09 -
dc.identifier.issn 1598-2351 -
dc.identifier.uri https://sciwatch.kiost.ac.kr/handle/2020.kiost/2428 -
dc.description.abstract This paper presents an investigation of the structural stability of cable-stayed bridges based on nonlinear analysis. In general, girders and masts of cable-stayed bridges are always subjected to compressive forces due to pre-tensioned stay cables. Cable-stayed bridges exhibit various geometric nonlinearities, such as the cable-sag effect, beam-column effect of girders and masts, and large displacement effect. In this study, the characteristics of the structural stability of cable-stayed bridges are investigated. Because of various geometric nonlinearities, nonlinear finite element analysis should be performed for stability analysis instead of conventional eigenvalue analysis. Furthermore, the initial shape analysis should be performed prior to live load analysis in order to consider the dead load condition rationally. A two-step analysis method, developed based on the theory of nonlinear finite element method, is presented in this study for stability analysis under live load cases. An intensive series of parametric studies is subsequently performed using three-span cable-stayed bridges. The main buckling modes are classified depending on the location of the critical members. Also, the effects of cable arrangement, girder-mast stiffness ratio, area, and the number of cables on the structural stability are extensively investigated. -
dc.description.uri 1 -
dc.language English -
dc.publisher KOREAN SOC STEEL CONSTRUCTION-KSSC -
dc.subject NONLINEAR-ANALYSIS -
dc.subject STATIC ANALYSIS -
dc.subject DEAD LOADS -
dc.subject FORCES -
dc.title Structural stability of cable-stayed bridges -
dc.type Article -
dc.citation.endPage 760 -
dc.citation.startPage 743 -
dc.citation.title INTERNATIONAL JOURNAL OF STEEL STRUCTURES -
dc.citation.volume 15 -
dc.citation.number 3 -
dc.contributor.alternativeName 원덕희 -
dc.identifier.bibliographicCitation INTERNATIONAL JOURNAL OF STEEL STRUCTURES, v.15, no.3, pp.743 - 760 -
dc.identifier.doi 10.1007/s13296-015-9019-1 -
dc.identifier.scopusid 2-s2.0-84944314326 -
dc.identifier.wosid 000363066400019 -
dc.type.docType Article -
dc.identifier.kciid ART002037260 -
dc.description.journalClass 1 -
dc.subject.keywordPlus NONLINEAR-ANALYSIS -
dc.subject.keywordPlus STATIC ANALYSIS -
dc.subject.keywordPlus DEAD LOADS -
dc.subject.keywordPlus FORCES -
dc.subject.keywordAuthor cable-stayed bridges -
dc.subject.keywordAuthor structural stability -
dc.subject.keywordAuthor nonlinear analysis -
dc.subject.keywordAuthor cable -
dc.subject.keywordAuthor beam-column effect -
dc.relation.journalWebOfScienceCategory Construction & Building Technology -
dc.relation.journalWebOfScienceCategory Engineering, Civil -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.description.journalRegisteredClass kci -
dc.relation.journalResearchArea Construction & Building Technology -
dc.relation.journalResearchArea Engineering -