Interference effects on aerodynamic wind forces between two buildings SCIE SCOPUS

DC Field Value Language
dc.contributor.author Kim, Wonsul -
dc.contributor.author Tamura, Yukio -
dc.contributor.author Yoshida, Akihito -
dc.date.accessioned 2020-04-20T02:55:54Z -
dc.date.available 2020-04-20T02:55:54Z -
dc.date.created 2020-01-28 -
dc.date.issued 2015-12 -
dc.identifier.issn 0167-6105 -
dc.identifier.uri https://sciwatch.kiost.ac.kr/handle/2020.kiost/2352 -
dc.description.abstract Wind-induced interference effects on overall wind loads and local wind loads on two buildings were studied in a series of the wind tunnel test on typical tall building models using a pressure measurement technique. In this study, five types of adjacent building models were considered with height ratios (H-r = 0.5, 0.7, 1, 1.5 and 2) and wind directions were considered from 0 degrees to 355 degrees in 5 degrees steps. Aerodynamic interference effects on base moments and local wind forces along nine height levels of the principal building are presented and discussed. As a result, interference effects (MIFMD and RIFMD) on along-wind base moment coefficients with H-r=1 and 1.5 significantly increased when the interfering building was close to the principal building. Moreover, when a higher interfering building was located at (X/B, Y/B)= (1.5, 1), mean wind loads and fluctuating wind loads in the along-wind and across-wind directions simultaneously increased. Mean and RMS along-wind local force coefficients at z/H=0.975 were significantly increased when the interfering building was located at (X/B, Y/B)=(1.5, 0). Variations of alongwind and across-wind local force coefficients along the height levels depended on the locations and height ratios of the interfering building. (C) 2015 Elsevier Ltd. All rights reserved. -
dc.description.uri 1 -
dc.language English -
dc.publisher ELSEVIER SCIENCE BV -
dc.subject TALL BUILDINGS -
dc.subject HIGHRISE BUILDINGS -
dc.subject PRESSURES -
dc.subject EXCITATION -
dc.title Interference effects on aerodynamic wind forces between two buildings -
dc.type Article -
dc.citation.endPage 201 -
dc.citation.startPage 186 -
dc.citation.title JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS -
dc.citation.volume 147 -
dc.identifier.bibliographicCitation JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, v.147, pp.186 - 201 -
dc.identifier.doi 10.1016/j.jweia.2015.10.009 -
dc.identifier.scopusid 2-s2.0-84945388439 -
dc.identifier.wosid 000367124700017 -
dc.type.docType Article -
dc.description.journalClass 1 -
dc.subject.keywordPlus TALL BUILDINGS -
dc.subject.keywordPlus HIGHRISE BUILDINGS -
dc.subject.keywordPlus PRESSURES -
dc.subject.keywordPlus EXCITATION -
dc.subject.keywordAuthor Interference effect -
dc.subject.keywordAuthor Interference factor -
dc.subject.keywordAuthor Local wind load -
dc.subject.keywordAuthor Structural wind load -
dc.subject.keywordAuthor Tall building -
dc.subject.keywordAuthor Wind tunnel test -
dc.relation.journalWebOfScienceCategory Engineering, Civil -
dc.relation.journalWebOfScienceCategory Mechanics -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.relation.journalResearchArea Engineering -
dc.relation.journalResearchArea Mechanics -
Appears in Collections:
Files in This Item:
There are no files associated with this item.

qrcode

Items in ScienceWatch@KIOST are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse