Behavior of Inter-cell for Open-cell Caisson Breakwater System
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서지혜 | - |
dc.contributor.author | 원덕희 | - |
dc.contributor.author | 박우선 | - |
dc.date.accessioned | 2020-07-15T12:52:38Z | - |
dc.date.available | 2020-07-15T12:52:38Z | - |
dc.date.created | 2020-02-11 | - |
dc.date.issued | 2018-04-04 | - |
dc.identifier.uri | https://sciwatch.kiost.ac.kr/handle/2020.kiost/23445 | - |
dc.description.abstract | Various methods have hitherto been proposed for interlocking adjacent caissons to enhance stability of harbor structures to resist the abnormally high waves [1],[2]. Among the methods, it was studied the method based on an open-cell caisson by filling materials in an inter-cell formed by two facing open-cells which consist of transverse walls. It is necessary to investigate the shear behavior of an inter-cell to secure the stability using calculating shear forces under wave loadings. In this paper, structural behaviors of open-cell caisson evaluated by FE analysis using commercial program [3] including stress distribution of filling materials, distribution subgrade reaction force, behavior evaluation of global system etc., [4],[5]. According to the analysis result, the open-cell caisson has good performance compare with the conventional caisson type. It was applicable in the assumption that filling materials was uniformly distributed in inter-cells, and further studies were worth consideration on other conditions including foundation. by filling materials in an inter-cell formed by two facing open-cells which consist of transverse walls. It is necessary to investigate the shear behavior of an inter-cell to secure the stability using calculating shear forces under wave loadings. In this paper, structural behaviors of open-cell caisson evaluated by FE analysis using commercial program [3] including stress distribution of filling materials, distribution subgrade reaction force, behavior evaluation of global system etc., [4],[5]. According to the analysis result, the open-cell caisson has good performance compare with the conventional caisson type. It was applicable in the assumption that filling materials was uniformly distributed in inter-cells, and further studies were worth consideration on other conditions including foundation. | - |
dc.description.uri | 1 | - |
dc.language | English | - |
dc.publisher | Computational Structural Engineering Institute of Korea (COSEIK) | - |
dc.relation.isPartOf | CODE 2018 | - |
dc.title | Behavior of Inter-cell for Open-cell Caisson Breakwater System | - |
dc.type | Conference | - |
dc.citation.conferencePlace | KO | - |
dc.citation.endPage | 328 | - |
dc.citation.startPage | 328 | - |
dc.citation.title | CODE 2018 | - |
dc.contributor.alternativeName | 서지혜 | - |
dc.contributor.alternativeName | 원덕희 | - |
dc.contributor.alternativeName | 박우선 | - |
dc.identifier.bibliographicCitation | CODE 2018, pp.328 | - |
dc.description.journalClass | 1 | - |